LK Series —— Flange mounting |
|
|
|
|
■
|
Rugged Industrial Sensor
|
■
|
Linear, Absolute Measurement
|
■
|
Non-Contact Sensing Technology
|
■
|
Linearity Deviation Less Than ±0.05%
|
■
|
Repeatability Within ±0.002%
|
|
|
|
|
|
|
|
Interface |
Analog
|
Modbus |
Output |
0~20mA,4~20mA; 0~10V,-10~+10V
|
RTU Signal,EIA-RS485/RS422 |
Stroke range |
100mm~2500mm |
Accuracy |
Linearity Deviation<±0.05%F.S.,Repeatability<±0.002%F.S. |
Thread |
Flange installation (4-M8), installation slope ≤5° |
Protection |
IP68, Pressure rating: 35MPa / 70MPa peak
|
Temperature |
- 40℃~+85℃ |
Voltage
|
Input : 24VDC (-15/+20%) , Polarity protection , Overvoltage protection |
Magnet |
DL42; DL52 |
■ Dimensions
|
|
|
NO. |
Define |
Analog
|
Modbus |
H |
Head length |
35mm |
Z |
Null Zone |
50mm
|
L |
Stroke Range |
100mm~2500mm |
N |
Dead Zone |
50mm |
D |
Rod O.D |
10mm
|
M |
Magnet O.D. |
DL42; DL52 |
■ Wiring & Diagnostic Display
|
Interface:Analog and Modbus
Analog
|
Pin
|
Cable
|
Define
|
Modbus
|
Pin
|
Cable
|
Define
|
|
1
|
GY
|
Output Signal
|
|
1
|
GY
|
N.C.
|
2
|
PK
|
DC Ground
|
2
|
PK
|
N.C.
|
3
|
YL
|
N.C.
|
3
|
YL
|
A(RS485)
|
4
|
GN
|
N.C.
|
4
|
GN
|
B(RS485)
|
5
|
BN
|
+24VDC(-15%/+20%)
|
5
|
BN
|
+24VDC(-15%/+20%)
|
6
|
WT
|
DC GND(0VDC)
|
6
|
WT
|
DC GND(0VDC)
|
|
|
|
|
|
|
|